Nye Technical Services, a family-owned commercial integrator in Harmony serving Pittsburgh-area businesses, handles in-house structured cabling (Cat 5e, Cat 6, and fiber) alongside network consulting and CCTV installation, and its featured camera partner is Hanwha Vision. A website is not proof for any installer, so verify in writing who pulls the cable, ask for certification test reports on every run, and confirm who configures VLANs, PoE budgets, and remote access.

TL;DR

  • Nye Technical Services, a family-owned Harmony integrator, runs its own structured cabling and also offers network consulting and CCTV, with Hanwha Vision as its featured camera partner.
  • Every copper camera run has a hard limit: a 100-meter channel, including a 90-meter permanent link. Longer runs need fiber, an extender, or a remote switch.
  • Budget PoE at the switch: PoE+ (802.3at) reserves 30 watts per port, so eight heated outdoor cameras can claim 240 watts.
  • Ask for permanent-link certification reports; one major cable-tester maker calls permanent-link testing best practice for new installations.
  • Standard contracts often permit subcontracting, so get the names of whoever pulls cable and configures switches in writing.

Which Types of Pittsburgh Installers Do Both Cabling and Networking?

Several kinds of local firms market both, though few say outright who does the work. The table groups what Pittsburgh-area installers said on their own websites in September 2026 by provider type.

Installer types that list both camera and cabling or network services (Pittsburgh-area websites, September 2026)
Provider type Cabling and network services listed What it says about who does the work
Local integrator (Nye Technical Services) Cat 5e, Cat 6, and fiber cabling; racks and patch panels; network consulting; CCTV Structured cabling handled in-house, alongside network consulting and CCTV
Local security and cabling installer Cameras with Cat6 and Cat6A cabling; some add fiber, data closets, switches, business Wi-Fi, and A/V One says it works without subcontractors; another says every drop is tested and certified to TIA/EIA standards
Other local and regional integrators IT and structured cabling or network infrastructure alongside video surveillance and access control Usually not stated; one says licensed master electricians do its electrical work
Voice and data cabling contractor Voice and data cabling plus IP camera and NVR installs Not stated

Larger providers organize the work differently. One large regional alarm company says it serves businesses through a mix of internal teams and a vetted network of approved contractors, a national provider’s network division sells managed network services to multi-site businesses, and one Pittsburgh integrator’s published proposal terms permit it to subcontract any of its services. None of that is unusual; it simply means you should ask who will be on your ladder and in your network closet.

How Nye Technical Services Handles Cabling and Network Setup

Nye Technical Services keeps structured cabling in-house alongside network consulting and CCTV, so the company that pulls and terminates the cable also configures the network the cameras run on. Its structured cabling installation covers Cat 5e, Cat 6, fiber optic, and backbone runs, with termination, labeling, tracing, troubleshooting, data racks, and patch panels. Its network consulting work includes infrastructure upgrades, network assessments, and business Wi-Fi.

Founder Vic Nye started in low-voltage wiring and CCTV more than five decades ago, and Bud Nye has led the family-owned company since 2017. Its featured video partner is Hanwha Vision, and for follow-up work Nye offers smart hands on-site support, including rack and stack and low-voltage maintenance. As of September 2026, Nye held a 5.0-star Google rating across 24 reviews, with review topics that include networking and quick response.

What Goes Wrong When Cabling and Network Work Are Split?

Most problems appear at the handoff between trades, and they are predictable.

  • Runs past the distance limit. A copper Ethernet channel is capped at 100 meters (about 328 feet), including a 90-meter (295-foot) permanent link and 10 meters of cords. A cabler who does not know where the PoE switch will sit can leave a far camera out of range.
  • A PoE budget that does not add up. At the switch, standard PoE (802.3af) allocates 15.4 watts per port, PoE+ (802.3at) 30 watts, and 802.3bt up to 90 watts. Eight heated outdoor cameras on PoE+ can claim 240 watts, so a switch with a smaller budget cannot power them all.
  • Video on the office network. Continuous recording competes with point-of-sale and office traffic unless cameras sit on their own VLAN or switch. H.265 needs only about half the bit rate of H.264, but only if cameras and recorder are set up for it.
  • Remote access nobody secured. When no one owns the firewall, remote viewing may be set up through automatic port opening; CISA advises disabling Universal Plug and Play on routers unless absolutely necessary.

Single Vendor or Split Contract: How Do They Compare?

One vendor for cable, switch, and cameras usually fits businesses without in-house IT; a split contract can work when an owner’s IT team coordinates the trades.

One installer versus split contractors for a business camera system
Factor One vendor for cabling, network, and cameras Split between cabling and camera contractors
Accountability One company answers for cable, switch, and camera faults Each contractor answers only for its own scope
Cable plan Runs planned around final camera and switch locations Cabler may not know final camera or switch positions
PoE sizing Switch sized against the full camera list, heaters included Left to whoever buys the switch
Network security VLANs, firewall rules, and remote access set up with the cameras Depends on your IT staff or a third vendor
Acceptance testing Certified cable plus a working camera at every drop Cable and cameras tested separately
Best fit Small and mid-size businesses without in-house IT Large projects with an owner’s IT team coordinating

Nye’s existing article on why use the same installer for cabling and cameras covers the accountability argument in more depth; the rest of this article focuses on how to check that an installer really does both.

How Do You Verify an Installer Really Does Both?

Ask for names, documents, and a network handoff rather than promises. These questions separate an integrator from a camera installer with a cabling subcontractor, and they apply to every installer, Nye included.

  1. Who pulls and terminates the cable: your employees or a subcontractor? Put the answer in the contract.
  2. Will you hand over certification results for every run? One major cable-tester maker calls permanent-link testing best practice for new installations, because a channel test can pass even when the permanent link underneath has failed.
  3. Which switch powers the cameras, what is its total PoE budget, and what will the camera list draw?
  4. How will camera traffic be separated from our business network, and who documents the IP addresses and VLANs?
  5. How will remote viewing work without opening inbound ports, and who holds the admin passwords when the job ends?
  6. Which credentials does the crew hold? BICSI credentials such as Installer 2 Copper, Technician, and RCDD can be checked in BICSI’s online credential holder search.
  7. Inside Pittsburgh, who holds the Electrical Trade License and pulls the permit for low-voltage work?

At closeout, expect a port map, an IP address list, the VLAN plan, test reports, and every administrator credential, turned over to you or your IT provider.

Frequently Asked Questions

Should security cameras be on a separate network from business computers?

In most businesses, yes. Putting cameras on their own VLAN or a dedicated switch keeps continuous video from competing with point-of-sale and office traffic, and it limits what an intruder can reach if a camera is compromised. The recorder and the few staff devices that need video can still be allowed through firewall rules, which is why one team should plan the cameras and the network together.

How far can an Ethernet cable run to a PoE camera?

A copper Ethernet channel tops out at 100 meters, about 328 feet, and that includes a 90-meter (295-foot) permanent link plus 10 meters of patch and equipment cords. The ANSI/TIA-568.2-D standard also recognizes a plug-terminated link that connects straight to a device such as a camera. Longer runs need fiber, a remote switch, or an extender.

How do you calculate a PoE budget for security cameras?

Add up what each camera’s PoE class reserves at the switch: 15.4 watts for standard 802.3af, 30 watts for PoE+, and 60 or 90 watts for the two 802.3bt types. Compare the total with the switch’s rated PoE budget on its spec sheet and leave headroom for added cameras. Heated outdoor cameras usually need a higher class than indoor domes, so count them separately.

Do you need a license to run camera cable for a business in Pittsburgh?

Pennsylvania has no statewide license for low-voltage, CCTV, or electrical contractors, so licensing is municipal. Inside Pittsburgh, commercial low-voltage systems of 50 volts or less are a listed electrical permit scope, and the City requires an Electrical Trade License for electrical work, with an exemption for equipment under 25 volts and 50 watts. Confirm your project with the Department of Permits, Licenses, and Inspections.

Nye Technical Services designs, cables, and configures commercial camera systems for Pittsburgh-area businesses from its office in Harmony, serving Allegheny, Butler, and Beaver counties. To have one team plan your cabling, switches, and cameras together, call 724-204-1750 or email sales@nyetechnicalservices.com to schedule a site survey.

Ready to level up your tech? Let’s schedule a site assessment.